CFP Alarmsense® Control Panels

The AlarmSense® CFP two-wire fire panel is designed to work with Apollo’s AlarmSense® range of detectors, call points, sounders and beacons. 

Most conventional fire systems are designed to work with two pairs of wires per zone: one pair for detection devices such as smoke detectors, heat detectors and manual call points; the other for alarm devices such as bells, sounders or strobes. By using different voltage bands for quiescent and alarm states, AlarmSense®components can be connected to the same pair of supply wires. When powered and controlled by the CFP two-wire fire panel, this reliable technology takes all the complexity out of fire alarm system design, leading to quicker, less expensive and more flexible installation.

Research shows an AlarmSense® two-wire system can achieve a 20-25% reduction of labour over a standard four wire conventional system.AlarmSense® devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation (HMOs).

Key Features

  • Designed to comply with EN54 Parts 2 and 4
  • Available with 2, 4 or 8 AlarmSense zone circuits (dependent on model purchased)
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
  • Four conventional sounder circuits (for use with non-AlarmSense sounders)
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU
  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones
  • Two on-board relays (Fire and Fault)
  • Two open-collector outputs (Remote and Reset)
  • ‘Class change’ and alert inputs
  • Installer-friendly design accommodates easy first fix and straightforward maintenance
  • Attractive flush or surface mountable plastic lid and enclosure – no bezel required
  • Low quiescent current
  • Multiple indicators
  • End of line units included (one per zone)
  • Ancillary system expansion connections provided for up to eight two-wire repeaters (one network driver card required per system) and optional relay boards
  • Space for two x 12V 3.4Ah VRLA batteries
  • Third-party LPCB tested
Part No.CFP AlarmSense Fire Panels and AncillariesFurther Information
F10004CFP AlarmSense 2 zone two-wire panel, keypad/keyswitch entry, does not extendEngineer's Manual
User Manual
F10005CFP AlarmSense 4 zone two-wire panel, keypad/keyswitch entry, does not extendEngineer's Manual
User Manual
F10006CFP AlarmSense 8 zone two-wire panel, keypad/keyswitch entry, does not extendEngineer's Manual
User Manual
F10010CFP 8 zone repeater panel, up to 8 per system, keypad/keyswitch entryEngineer's Manual
F10011CFP network driver card (one required per repeater system, fit at main)
F10012CFP relay output card (reset, fault, aux fire and remote relays)Engineer's Manual
F10013CFP relay output card (reset, fault, aux fire and remote relays, plus 8 output per zone relays)Engineer's Manual
F10014CFP relay output card (8 output per zone relays)
F10015CFP relay output card (provides 4 output per zone relays)
F10016CFP relay output card (provides 2 output per zone relays)